Arc Flash Incidents • Estimated 5-10 arc flash incidents per day • Estimates as to the cost of a major injury where >50percent of body burned (skin grafts, therapy) and related costs (replacement worker, rehabilitation, etc.) NFPA 70E defines the arc flash boundary as "…a distance from a prospective arc source within which a person could receive a second degree burn if an electrical arc flash were to occur.". The arc flash boundary is calculated to 1.2 calories/cm2 of incident energy. The issue here is the heat Limited Approach Boundary: An approach limit at a distance from an exposed The Arc Flash Boundary marks the distance from the equipment at which the Incident Energy of an arc flash would be 1.2 cal/cm². If an arc flash explosion occurs within this boundary, it is considered that an electrical worker would be exposed to a curable second degree burn (1.2 . Sounds crazy but that's what it is. Arc rated PPE exists on a continuum and is determined during the assessment process. This means, for racking on a switchboard with a 42 kA fault current, clearing time of 0.33 seconds you need to use category 4 PPE, and the arc flash boundary is 4.3 meters. PPE Category 1: Minimum Arc Rating 4 cal/cm2.

NFPA 70E establishes the default flash protection boundary at 4 feet for low voltage ( < 600V ) systems where the total fault exposure is less than 5000 amperes-seconds (fault current in amperes multiplied by the upstream device clearing time .

Eye protection. The analysis can take one of several different forms. Arc Flash is the result of a rapid release of energy due to an arcing fault between a phase bus bar and another phase bus bar, neutral or a ground. NFPA 70E® compliance saves lives, reduces liability, and helps avoid unexpected downtime and revenue loss.Now, the 2015 Standard takes another big step in changing the way America works. Many of these incidents could have been prevented through compliance with the latest safety codes and standards.

Approach limit boundaries for Arc Flash and Shock Based on NFPA 70E-2015 Standard Editions 1.2 cal/cm2 onset of 2nd degree skin burn Arc flash boundary Unqualified personnel + Arc-rated PPE, awareness & continuously escorted by a qualified person Arc flash boundary Qualified person Plus competent for work task Plus risk assessment procedure The flash protection boundary is based on voltage, the available fault current and the time it takes for the upstream protective device to operate and clear the fault. e-Hazard arc flash studies (or arc flash or hazard analysis) are conducted at your facility by one of our trained experts, qualified to evaluate your electrical system.

These boundaries trigger multiple requirements in 70E including but not limited to determining the type and level of PPE and qualifications required to cross into each level. When the arc flash boundary is the . Identify equipment and components that present a significant risk of arc flash.

Specifically, the revised definition of arc flash boundary no longer uses the term "second degree burn" but instead "at which incident energy equals 1.2 cal/cm2.", and the revised informational note references the Stoll skin burn injury model. Arc flash hazard analysis: A study investigating a worker's potential exposure to arc-flash energy, conducted for the purpose of injury prevention and the determination of safe work practices, arc flash boundary, and the appropriate levels of personal protective equipment ("PPE"). The arc flash boundary is the distance away from an arc flash where someone would be able to receive a second-degree burn.

Voice your opinion!

The arc flash boundary is detailed as a safe approach distance from parts or equipment that is currently energized, also known as "live.". Arcing time. NFPA 70E recommends Limited and Restricted Approach Boundaries to protect workers from electric shock, and a separate Arc Flash Boundary to protect them from burns in the event of an arc flash. Primarily, arc flash PPE is divided into the following subgroups: Head, face, neck and chin protection. employee within the arc flash boundary.

DB = separation of the flash protection boundary from the arcing point (inches) NFPA 70E TABLES - FLASH PROTECTION BOUNDARY NFPA 70E presents a simple method of assessing flash protection boundary. The revised definition of arc flash boundary no longer uses the term "Second degree burn" Instead, "Arc flash hazard exists when incident energy equals 1.2 cal/cm2 " - "Second degree" has been replaced by the term "Stoll skin Burn". OR. An arc flash is an explosive flash of light that jumps between two points on high powered electrical equipment. The NFPA 70E defines three boundaries for electrical workers to observe. Distance. As part of a larger training and safety . Preplanning your facility will enhance you staff's safety. An arc-rated balaclava with an arc-rated faceshield is an option when the back of the head is within the arc flash boundary and the anticipated incident energy exposure is 12 cal/cm2 or less. The program provides a clear explanation of the two approach boundaries used for shock protection, the Limited Approach Boundary and the Restricted Approach Boundary, as well as the approach boundary used for arc flash protection, the Arc-Flash Boundary. Incident Energy Analysis.

7 LIVE PARTS Existing definition of "live parts" - Electric conductors, buses, terminals, or components that are uninsulated or exposed and a shock hazard . Check out previous posts in this series which offer valuable information on topics such as, what is an arc flash, and arc flash causes, characteristics, ratings, and more. In an effort to limit electrical injuries in the workplace, the Occupational Safety and Health Administration (OSHA) has passed law that only allows a "Qualified" person to work on or around energized circuits or equipment. Flash Protection Boundary (FPB) The FPB is a safe approach distance from energized equipment or parts. The third boundary is the arc flash boundary.

1584 'IEEE Guide for Performing Arc-Flash Hazard Calculations'.

When the arc flash boundary is the . An arc flash boundary is the distance from the equipment in question to the point where the energy that would be present in an arc flash is 1.2 cal/cm2. The introduction to this section provides a summary of the arc flash training requirements: "Such employees shall be trained to understand the specific hazards associated with electrical energy.

Remember, PPE should be viewed as the last line of protection.

This is the final post in a six-part "Fundamentals of Arc Flash" series. Arc faults are generally limited to systems where the bus voltage is in excess of 120 volts. The definition of "arc flash boundary" from NFPA 70E contains an informational note that references "the onset of a second degree burn on unprotected skin is likely to occur at an exposure of 1.2 cal/cm 2 .". Note (2): All dimensions are distance from exposed energized electrical conductors or circuit part to employee. Arc flash results in the production of heat and fire that can cause burns. Having knowledge of when it is safe and what the appropriate boundaries are can help mitigate risk associate with electrical hazards.

Any equipment that poses the risk of an arc flash, needs to be labelled with a warning.

An arc flash can have deadly consequences, thus everyone who works with . Hazard awareness and arc flash safety training mitigates the risk of serious bodily injury or property loss. c. The working distance is the distance from a person's face and chest to the prospective arc source. In a fraction of a second, an electrical incident can claim lives and cause permanently disabling injuries. Arc flash hazard is based on: Fault current. This is presented in Table 4. Arc Flash Protection Boundary. An arc flash risk assessment is a process to determine if an arc flash hazard exists. This could include arc rated shirt, pants, face shield, leather gloves or a heavy-duty arc-rated suit. Definitions Incident energy (arc flash energy) • The amount of thermal energy impressed on a surface, a certain Information shown in this table is an estimate - the actual arc When an electrical current jumps between two points it is called an arc. Flash Hazard Analysis - A study investigating a worker's potential exposure to arc-flash energy, conducted for the purpose of injury prevention and the determination of safe work practices and the appropriate levels of PPE. 2.

, is written with the non-QEW in mind. This is presented in Table 4. A qualified person who works closer than 48 inches to live parts must wear personal protective clothing (PPE) including flame-resistant (FR) clothing. the potential arc flash hazard. According to the 2004 edition of 70E the definition of the flash protection boundary was "an approach limit at a distance from exposed live parts within which a person could receive a second degree burn if an electrical arc flash were to occur". PS: There are changes to the definition of arc flash boundary in the upcoming NFPA 70E Standard for Electrical Safety in the Workplace.

When an arc flash hazard exists, an approach limit at a distance from an arc source at which an incident energy level of 1.2 cal/cm2. 2. Studies can be customized to include fault current and coordination analysis, Personal Protective Equipment (PPE) Level recommendations, Arc Flash Equipment Labeling and more .

That's the distance where a worker without appropriate PPE would receive second-degree burns. (2004 NFPA 70E) Flash Protection Boundary - An approach limit at a distance from exposed live parts within Arc blast results in the production of pressure, shrapnel, and sound which can cause associated injuries. The other hazards of electricity are arc flash and arc blast.

Arcing time. In more technical terms, it is defined as the distance at which, in the event of an arc flash, a worker would be exposed to a thermal event with incident . The arc flash hazard analysis should determine the arc flash boundary (AFB) and level of personal protective equipment (PPE) that the worker must wear. electrical arc flash were to occur. 2. They used to call it the arc flash protection boundary until someone pointed out that it did not protect anyone from anything (well maybe third-degree burns).

It is an OSHA-recognized consensus standard; therefore, the arc-flash boundary has legal weight as a boundary that must be observed in workplaces in order for employers to meet their general duty obligations for workplace safety. IV. Arc flash dangers such as shock, electrocution, and arc blast are serious hazards. Note(1): For arc flash boundary, see 130.5(A). 1. Arc flash personal protective equipment (PPE) is a combination of clothing and safety equipment worn for protection from arc flash and shock hazard by a person performing electrical work.

Flash Protection Boundary (outer boundary): The flash boundary is the farthest established boundary from the energy source.

PROTECTION BOUNDARIES. Flash protection boundary (outer boundary) The flash protection boundary is the farthest established boundary from the energy source. DB = separation of the flash protection boundary from the arcing point (inches) NFPA 70E TABLES - FLASH PROTECTION BOUNDARY NFPA 70E presents a simple method of assessing flash protection boundary. Requiring a single layer of arc-rated PPE, workers need the following clothing: Required Clothing: Long Sleeve Shirt (or Jacket) and Pants or AR Coverall with minimum arc rating of 4 cal/cm 2.

Determine Flash Protection Boundary (FPB). Arc-Flash Boundary.

Arc Flash Risk Assessment. If an arc flash occurred, this boundary is where an employee would be exposed to a curable second degree burn (1.2 calories/cm 2). The definition of a qualified electrical worker is explained in addition to the knowledge . This is the level at which it will cause only second-degree burns rather than third-degree. If it does, the risk assessment shall determine the appropriate safety-related work practices, the arc flash boundary, and the personal protective equipment (PPE) to be used within the arc flash boundary. The Flash Protection Boundary is the calculated safe working distance from electrical equipment which would not expose the employee to the hazards associated with an electrical arc flash.

protection, workers exposed to arc flash events can suffer third-degree burns, collapsed lungs, vision loss, eardrum ruptures, puncture wounds, . At this energy level, an unprotected worker would probably receive second-degree burns as a result of an arc flash. Information shown in this table is an estimate - the actual arc Definitions Incident energy (arc flash energy) • The amount of thermal energy impressed on a surface, a certain The IEEE 1584 arc flash boundary equations can also be used to calculate the arc flash boundaries with boundary energy other than 1.2 cal/cm^2 such as onset to 2nd degree burn energy.

That's the distance where a worker without appropriate PPE would receive second-degree burns.

The arc flash boundary is based on voltage, the available fault current and the time it takes for the upstream protective device to operate and clear the fault.

There are two methods to select the appropriate PPE.

3. Arc Flash Boundary. PPE CAT 1 represents the lowest level in which Arc Rated PPE s required. • Flash Protection Boundary (outer boundary) Who is a Qualified Worker? Sept. 5, 2012 Applying notes from Annexes C, D, and H of 2012 NFPA 70E. NFPA 70E Electrical Arc Flash is the leading standard for determining electrical hazards and protecting employees.

They shall be trained in safety-related work practices and procedural requirements, as necessary to provide protection from the electrical hazard . Typical working distances, Employees should keep outside these boundaries during ordinary work. The arc flash boundary is calculated to 1.2 calories/cm2 of incident energy.

with safe and effective electrical arc flash risk controls being implemented by electrical workers can include (but are not limited to): 1. This PPE is for arc-flash and arch-blast protection, not . Flash Protection Boundary. The work permit shall include the results of an Arc Flash Risk Assessment The Arc Flash Risk Assessment shall determine 130.5(1) - Appropriate safety related work practices • Including Maintenance Switching - Arc Flash Boundary - PPE to be used within the arc flash boundary NEC 110-16 requires equipment to be marked to warn of arc • And then the social costs 8 This is the shortest distance at which a person working at the time of an arc-flash may receive permanent injury (the onset of a second degree burn or worse) if not properly protected by flame-resistant (FR) clothing. 15 New Definitions that will be in the new edition of NFPA 70E (2004): The formulas are valid for systems ranging from 208 V to 15 kV.